1 · Your loads

One line per load, measured as in Chapter 3. Watts × hours a day = watt-hours (Wh) a day; or type the Wh a day read on a plug-in meter (Appendix A, Worksheet 1). Tick “Stays on” for a load that keeps running while nobody is there.

All loads
0 Wh a day
Loads that stay on
0 Wh a day

2 · Your site and your battery

From PVWatts, for a 1-kW trial system: your worst month’s kWh ÷ the days in that month (Chapter 3; Appendix A, Worksheet 2).

Enter a value between 0.5 and 8. Check the PVWatts figure and the division by the days of the month.

A choice, not a calculation: Chapter 3’s 3 to 7 days, more for critical loads and places that are hard to reach.
This book’s examples use 80% (Chapter 3).
The capacity the spec sheet lists at the coldest place the battery will sit. 100 if it lists no loss.

Some values are empty or out of range: the results wait until they are filled in.

3 · Results: at home and away

“At home” sizes for every load. “Away” sizes only for the loads that stay on while nobody is there, as for an empty cabin.

At homeAway
Use in the worst month— Wh a day— Wh a day
Energy the battery must give— Wh— Wh
Battery size— Wh— Wh
Battery size in amp-hours— Ah— Ah
Smallest array— W— W
Number of panels——
What the panels make on an average worst-month day— Wh— Wh
Margin a day— Wh— Wh
Days to refill the battery after a sunless stretch——
Charge current, a first indication— A— A

A long refill means more panels: raise the number of panels below and watch the margin and the refill change (Chapter 3). The panel number is a floor, not a target.

The charge current is the array’s watts ÷ the battery voltage, the way the book checks a controller. The controller’s own rating, the wire and the fuses come from its manual and Appendix B.

4 · Your projects

    What this calculator does not do

    It does not size wires or fuses (Appendix B), choose models or makes, or read any data from the internet. It works only with the numbers you type in.